LENOVO SAN – Storage D1224 SFF Disk Expansion with Dual SAS IO Modules
Abstract
The Lenovo Storage D1212 and D1224 Disk Expansion Enclosures offer 12 Gbps SAS direct-attachedstorage expansion capabilities that are designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The D1212 and D1224 deliver enterprise-class storage technology in a cost-effective solution with flexible drive configurations and RAID or JBOD (non-RAID) host connectivity.
This product guide provides essential pre-sales information to understand the structure of the D1212 and D1224 drive enclosure offerings, their key features and specifications, components and options, and configuration guidelines.
This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the D1212 and D1224 and consider their use in IT solutions.
Change History
Changes in the June12 update:
- AddedLenovo Storage 1.92TB 1DWD 2.5″ SAS SSD
- AddedLenovo Storage 3.84TB 3DWD 2.5″ SAS SSD
Introduction
The Lenovo Storage D1212 and D1224 Disk Expansion Enclosures offer 12 Gbps SAS direct-attached storage expansion capabilities that are designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The D1212 and D1224 deliver enterprise-class storage technology in a cost-effective solution with flexible drive configurations and RAID or JBOD (non-RAID) host connectivity.
The D1212 and D1224 expansion units are designed for a wide range of workloads, including big data and analytics, video surveillance, media streaming, private clouds, file and print serving, e-mail and collaboration, and databases. They also well-suited for software defined storage (SDS) and Windows Server solutions with Storage Spaces.
Figure 1. Lenovo Storage D1212 and D1224 Disk Expansion Enclosures
Did you know?
The D1212 and D1224 expansion enclosures offer flexible drive configurations with the choice of 2.5-inch and 3.5-inch drive form factors, 10K or 15K rpm SAS and 7.2K rpm NL SAS hard disk drives (HDDs) and self-encrypting drives (SEDs), and SAS solid-state drives (SSDs).
With support for daisy chaining, the D1212 can be scaled up to 1.15 PB for capacity-optimized configurations with HDDs, and the D1224 can be scaled up to 192 drives for performance-optimized configurations.
The D1212 and D1224 expansion units support12 Gbps SAS connectivity, which doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.
Key features
Key features and benefits provided by the D1212 and D1224storage expansion enclosuresinclude:
- Versatile, scalable storage expansion with dual Environmental service Module (ESM) configurations for high availability and performance
- Flexible host connectivity to match diverse client needs for direct attach storage with support for 12 Gb SAS RAID adapters for advanced data protection or 12 Gb SAS Host Bus Adapter (HBA) for maximum JBOD performance
- 12 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) drives in the D1212 enclosure or 24x 2.5-inch small form factor (SFF) drives in theD1224enclosure
- Scalabilityof up to 96 LFF or 192 SFF drives per RAID adapter or HBAwith the attachment of up to eight D1212 orD1224daisy-chainedexpansion enclosures, or a combination of both,to satisfy growing needs for storage capacity and performance
- Flexibility in storing data on high performance SAS SSDs, performance-optimized enterprise SAS HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form factors on a single RAID adapter or HBA to perfectly meet performance and capacity requirements for various workloads
- Self-encrypting drives with a supported RAID adapterallow clients to secure their sensitive data and to comply with various security regulations when required
- Support multiple host attachments and SAS zoning for storage partitioning
The D1212 and D1224 are designed to support the complete range of data storage requirements, from highly utilized applications to high-capacity, low usage applications.
The following 3.5-inch SAS drives are supported by the D1212:
- High performance solid-state drives (3 drive writes per day [DWD] and 10 DWD): 400 GB
- Performance-optimized, enterprise class disk drives:900 GB 10K rpm
- High-capacity, archival-class nearline disk drives: 2 TB, 4 TB, 6 TB, 8 TB, 10 TB, and 12 TB 7.2K rpm
- High-capacity, archival-class nearlineself-encryptingdisk drives: 4 TB 7.2K rpm
The following 2.5-inch SAS drives are supported by the D1224:
- Capacity optimized solid-state drives (1 DWD): 3.84 TB, 7.68 TB, and 15.36 TB
- Mainstream solid-state drives (3 DWD): 400 GB, 800 GB,1.6 TB, and 3.84 TB
- High performance solid-state drives (10 DWD): 400 GB, 800 GB, and 1.6 TB
- High performance self-encrypting solid-state drives (10 DWD): 800 GB
- Performance-optimized, enterprise class disk drives
- 300 GB,600 GB, and 900 GB 15K rpm
- 600 GB, 900 GB, 1.2 TB,1.8 TB, and 2.4 TB 10K rpm
- Performance-optimized, enterprise class self-encryptingdisk drives: 1.2 TB 10K rpm
- High-capacity, archival-class nearline disk drives: 1 TB and 2 TB 7.2K rpm
Additional drives and expansion units are designed to be dynamically added with virtually no downtime (operating system dependent), helping to quickly and seamlessly respond to growing capacity demands.
The D1212 and D1224 expansion enclosures are designed to offer high levels of system and data availability with the following technologies:
- Dual ESMs provide redundant paths from a supported RAID controller to the drives in theenclosuresfor I/O load balancing and failover
- Dual-port drives (both HDDs and SSDs) with automatic drive failure detection and RAID rebuild with global hot spares with a supported RAID adapter
- Redundant hardware, including host ports, ESMs, and power and cooling modules (PCMs)
- Hot-swappable and customer replaceable components, including ESMs, PCMs, and drives
Components and connectors
The following figure shows the front of the D1212 drive expansion enclosure.
Figure 2. Front view of the D1212 drive enclosure
The following figure shows the front of the D1224 drive expansion enclosure.
Figure 3. Front view of the D1224 drive enclosure
The following figure shows the rear of the D1212 and D1224 drive enclosures.
Figure 4. Rear view of the D1212 and D1224 drive enclosures
Note: The ESMs (shown in Figure 4) have additional service ports with a specialized connector, and these ports are reserved for use by a Lenovo service technician.
System specifications
The following table lists the D1212 and D1224system specifications.
Attribute | Specification |
---|---|
Form factor | 2U rack mount |
Number of ESMs | 2 |
Expansion ports | 3x 12 Gb SAS x4 (Mini-SAS HDSFF-8644)ports (A, B, C)per ESM |
Drive bays |
Intermix of SFF and LFF enclosures is supported. |
Drive technologies | SAS and NL SAS HDDs and SEDs; SAS SSDs. Intermix of HDDs, SEDs, and SSDs is supported within an enclosure, but not within a RAID array. |
Drive connectivity | Dual-ported 12 Gb SAS drive attachment infrastructure. |
Drives | SFF drives:
LFF drives:
|
Storage capacity |
|
Host adapters | RAID adapters:
Host bus adapters (non-RAID):
|
Host operating systems | Microsoft Windows Server 2008 R2, 2012 R2, and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere5.5, 6.0, and 6.5. |
Cooling | Redundant cooling with two fans built into power and cooling modules (PCMs). |
Power supply | Two redundant hot-swap 580 W AC power supplies built into PCMs. |
Hot-swap parts | ESMs,drives, PCMs. |
Management interfaces | SAS EnclosureServices, 10/100 Mb Ethernet for external management. |
Security features | SAS zoning, self-encrypting drives (SEDs). |
Warranty | Three-year customer-replaceable unit, parts delivered limited warranty with 9×5 next business day response. |
Service and support | Optional warranty service upgrades are available through Lenovo: Technician installed parts, 24×7 coverage, 2-hour or 4-hour response time, 6-hour or 24-hour committed repair, 1-year or 2-year warranty extensions, YourDrive YourData, remote technical support, hardware installation. |
Dimensions | Height: 88 mm (3.5 in), width: 443 mm (17.4 in), depth: 630 mm (24.8 in) |
Maximum weight |
|
Models
The following table lists the relationshipmodels of the D1212 and D1224 driveenclosures.
Description | Part number |
---|---|
LFF models | |
Lenovo Storage D1212 LFF Chassis, Dual ESM(US English documentation) | 4587A11* |
Lenovo Storage D1212 LFF Chassis, Dual ESM(Simplified Chinese documentation) | 4587A1C^ |
Lenovo Storage D1212 LFF Chassis, Dual ESM(Japanese documentation) | 4587A1J** |
SFF models | |
Lenovo Storage D1224 SFF Chassis, Dual ESM(US English documentation) | 4587A31* |
Lenovo Storage D1224 SFF Chassis, Dual ESM(Simplified Chinese documentation) | 4587A3C^ |
Lenovo Storage D1224 SFF Chassis, Dual ESM(Japanese documentation) | 4587A3J** |
*Available worldwide (except China and Japan)
^ Available only in China
** Availableonly in Japan
The following table lists the TopSeller models of the D1212 and D1224 driveenclosures.
Description | Part number |
---|---|
LFF models – North America (NA) and Europe, Middle East, and Africa (EMEA) | |
Lenovo Storage D1212 LFF Dual ESM Disk Expansion Enclosure (US English documentation) | 4587E11 |
LFF models – Brazil and Latin America | |
Lenovo Storage D1212 LFF Chassis, Dual ESM,4x 2TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EAU |
Lenovo Storage D1212 LFF Chassis, Dual ESM,4x 4TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EBU |
Lenovo Storage D1212 LFF Chassis,Dual ESM, 4x 6TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587ECU |
Lenovo Storage D1212 LFF Chassis,Dual ESM, 4x 8TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EDU |
Lenovo Storage D1212 LFF Chassis, Dual ESM, 8x 2TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EEU |
Lenovo Storage D1212 LFF Chassis, Dual ESM, 8x 4TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EFU |
Lenovo Storage D1212 LFF Chassis, Dual ESM, 8x 6TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EGU |
Lenovo Storage D1212 LFF Chassis, Dual ESM, 8x 8TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EHU |
Lenovo Storage D1212 LFF Chassis, Dual ESM, 12x 2TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EIU |
Lenovo Storage D1212 LFF Chassis,Dual ESM, 12x 4TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EJU |
Lenovo Storage D1212 LFF Chassis, Dual ESM, 12x 6TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587EKU |
Lenovo Storage D1212 LFF Chassis, Dual ESM, 12x 8TB 3.5″ HDDs, 4x 0.5m SAS cables | 4587ELU |
SFF models -North America (NA) and Europe, Middle East, and Africa (EMEA) | |
Lenovo Storage D1224 SFF Dual ESM Disk Expansion Enclosure (US English documentation) | 4587E31 |
SFF models – Brazil and Latin America | |
Lenovo Storage D1224 SFF Chassis, Dual ESM, 9x 1.2TB 10K HDDs, 4x 0.5m SAS cables | 4587E6U |
Lenovo Storage D1224SFF, Dual ESM, 9x 1.2TB 10K HDDs,2x 400GB SSDs, 4x 0.5m SAS cables | 4587E2U |
Lenovo Storage D1224 SFF, DualESM, 9x 1.2TB 10K HDDs,4x 400GB SSDs, 4x 0.5m SAS cables | 4587E4U |
Lenovo Storage D1224 SFF Chassis, Dual ESM, 18x 1.2TB 10K HDDs, 1x 0.5m SAS cable | 4587E5U |
Lenovo Storage D1224 SFF, Dual ESM, 18x 1.2TB 10K HDDs,2x 400GB SSDs, 4x 0.5m SAS cables | 4587E1U |
Lenovo Storage D1224 SFF, Dual ESM, 18x 1.2TB 10K HDDs,4x 400GB SSDs, 4x 0.5m SAS cables | 4587E3U |
The part numbers for the D1212 andD1224drive enclosures include the following items:
- One LFF or SFF chassis with the following components:
- Dual 3-portenvironmental service modules
- Two power and cooling modules
- Drives (select models; see Table 2 and Table 3 for details)
- Two 1.5m, 10A/100-250V, C13 to IEC 320-C14 rack power cables
- External 0.5m12Gb SAS cables (select models; see Table 2 and Table 3 for details)
- Lenovo Storage 12Gb SAN Rack Mount Kit – Rails 25″-36″
- Documentation package
Host connectivity
The D1212 and D1224drive enclosures support dual environmental service module (ESM) configurations. Each ESM has three 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644 connectors) labeled A, B,and C. These ports are used for connections to a supported RAID adapter or HBA installed in a serverand for daisy chaining the D1212 and D1224 enclosures between each other.
Port A on each ESM is used for connectingtheexternal SASports on the RAID controller or HBA to the enclosure, or for connecting Port C on each ESMin the adjacent enclosure for daisy chaining.
Port Bon each ESM is used for connectingtheexternal SASports on the RAID controller or HBA to the enclosure. Daisy-chaining does not use Port B for connections between adjacent enclosures.
Port C on each ESM is used for connectingtheexternal SASports on the RAID controller or HBA to the enclosure, or for connecting Port Aon each ESMin the adjacent enclosure for daisy chaining.
The expansion enclosures support single I/O path and dual I/O path connectivity topology. For single I/O path configurations,each port on the adapter can be connected to a separate chain of expansion enclosures by using the ESM A in each connected enclosure. For dual I/O path configurations, each port on the 2-port RAID adapter or HBA is connected to a different ESM chain withinthe same chain of enclosures. For specific configuration limits, refer to SAS RAID controllers and HBAs.
For SAS RAID controllers, the controller’s firmware manages multiple I/O paths from the controller to SAS drives. For SAS HBAs, the host operating system runs multi-pathing software to manage multiple I/O paths.
Up to eight D1212 or D1224drive enclosures, or a combination of both, can be daisy-chained with support for up to four hosts attached to the chain.Without daisy-chaining,a standalone D1224driveenclosure can support up to six directly attached hosts.In addition, up to two D1212and up to two D3284drive enclosures, or one D1224and up to two D3284drive enclosures can be daisy-chained with support for up to two hosts attached to the chain.
The following figures illustrate different host connectivity topologies.
Figure 5. Connectivity topology with one host
Figure 6. Connectivity topology with twohosts
Figure 7. Connectivity topology with fourhosts
For topologies with four or more hosts, SAS Y-cables are required to connect the hosts to the drive enclosure. The SAS Y-cable allows two hosts be connected to one SAS port on the ESM.The Y-cables and standard cables are mutually exclusive, that is, either Y-cables or standard cablescan be used to connect thehosts to the same drive enclosure, but not both types.
The SAS zoning feature of the D1212 and D1224specifieshow multiple hosts access drives in the enclosures.If SAS zoning is disabled, all attached hosts can access all drives in the enclosures, which is typically usedin standalone single-host or clustered multi-host environments, where all cluster nodes need access to all drives.If SAS zoning is enabled, each connected host has exclusive access to a predefined set of drives in the same enclosure, and multiple hosts are isolated from each other.
Configuration notes:
- Attachment of more than one host to the same enclosure without SAS zoning is supported with HBAs only (RAID controllers are not supported). While all attached hosts are capable of accessing all drives in the enclosures, the clustering software running on the hostscontrols whichcluster nodes have access to the drives at any given time.
- With SAS zoning enabled, only standalone enclosures without daisy-chaining can be partitioned for multiple host access.
The supported zone configurations are shown in the following table.
Note: Mode 0 means thatzoning is disabled.
Zoning mode |
Number of zones |
Maximum number of hosts |
Zone number |
Host ports | Expansion ports |
Drive bays | |
---|---|---|---|---|---|---|---|
D1212 | D1224 | ||||||
Zoning withSAS standard cables | |||||||
Mode 0 | 1 | 2 | 1 | A, B | C | 0-11 | 0-23 |
Mode 1 | 2 | 2 | 1 | A | C | 0-1, 4-5, 8-9 | 0-11 |
2 | B | 2-3, 6-7, 10-11 | 12-23 | ||||
Mode 2 | 3 | 3 | 1 | A | N/A | 0-3 | 0-7 |
2 | B | 4-7 | 8-15 | ||||
3 | C | 8-11 | 16-23 | ||||
Zoning withSAS Y-cables | |||||||
Mode 3 | 3 | 3 | 1 | A.1 | C | 0-3 | 0-7 |
2 | A.2 | 4-7 | 8-15 | ||||
3 | B.1 | 8-11 | 16-23 | ||||
Mode 4 | 4 | 4 | 1 | A.1 | C | 0, 4, 8 | 0-5 |
2 | A.2 | 1, 5, 9 | 6-11 | ||||
3 | B.1 | 2, 6, 10 | 12-17 | ||||
4 | B.2 | 3, 7, 11 | 18-23 | ||||
Mode 5 | 6 | 6 | 1 | A.1 | N/A | N/A | 0-3 |
2 | A.2 | 4-7 | |||||
3 | B.1 | 8-11 | |||||
4 | B.2 | 12-15 | |||||
5 | C.1 | 16-19 | |||||
6 | C.2 | 20-23 |
The following table lists ordering information for the SAS cables.
Description | Part number | Feature code | Maximum quantity per one D1212 or D1224 |
---|---|---|---|
Connectivity cables – Mini-SAS HD Host Adapter to Expansion | |||
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable | 00YL847 | AU16 | 6 |
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable | 00YL848 | AU17 | 6 |
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable | 00YL849 | AU18 | 6 |
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable | 00YL850 | AU19 | 6 |
External MiniSAS HD 8644/MiniSAS HD 8644 6M Cable | 00KH452 | AUJY | 6 |
External MiniSAS HD 8644/2xMiniSAS HD 8644 2M Y-Cable | 01DC164 | AU1A | 6 |
Connectivity cables – Expansion to Expansion | |||
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable | 00YL847 | AU16 | 2 |
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable | 00YL848 | AU17 | 2 |
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable | 00YL849 | AU18 | 2 |
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable | 00YL850 | AU19 | 2 |
External MiniSAS HD 8644/MiniSAS HD 8644 6M Cable | 00KH452 | AUJY | 2 |
Drives
The D1212 drive enclosure supportsup to 12 LFF hot-swap drives, and the D1224 drive enclosure supports up to 24 SFF hot-swap drives.The following tables listdrive options for the D1212 and D1224 drive enclosures.
Description | Part number | Feature code | Maximum quantity per one D1212 |
---|---|---|---|
3.5-inch SAS hot-swap HDDs | |||
Lenovo Storage 900GB 10K SAS Hybrid trayHDD (2.5″ in 3.5″) | 01DC182 | AU1G | 12 |
3.5-inch NL SAS hot-swap HDDs | |||
Lenovo Storage 2TB 7.2K 3.5″ NL-SAS HDD | 00YH993 | AU1F | 12 |
Lenovo Storage 4TB 7.2K 3.5″ NL-SAS HDD | 01DC487 | AU1D | 12 |
Lenovo Storage 6TB 7.2K 3.5″ NL-SAS HDD | 00YG668 | AU1C | 12 |
Lenovo Storage 8TB 7.2K 3.5″ NL-SAS HDD | 00YG663 | AU1B | 12 |
Lenovo Storage 10TB 7.2K 3.5″ NL-SAS HDD | 01DC626 | AU3S | 12 |
Lenovo Storage 12TB 7.2K 3.5″ NL-SAS HDD | 4XB7A09100 | B102 | 12 |
3.5-inch NL SAS hot-swap SEDs | |||
Lenovo Storage 4TB 7.2K 3.5″ NL-SAS SEDHDD | 00YG673 | AU1E | 12 |
3.5-inch SAS hot-swap SSDs (10 DWD) | |||
Lenovo Storage 400GB 3DWD SAS SSD – Hybrid Tray (2.5″ in 3.5″) | 01GV682 | AV2H | 12 |
3.5-inch SAS hot-swap SSDs (10 DWD) | |||
Lenovo Storage 400GB 10DWD SAS SSD – Hybrid tray (2.5″ in 3.5″) | 01CX642 | AV2G | 12 |
Description | Part number | Feature code | Maximum quantity per one D1224 |
---|---|---|---|
2.5-inch SAS hot-swap HDDs | |||
Lenovo Storage 300GB 15K 2.5″ SAS HDD | 01DC197 | AU1J | 24 |
Lenovo Storage 600GB 10K 2.5″ SAS HDD | 01DC427 | AU1Q | 24 |
Lenovo Storage 600GB 15K 2.5″ SAS HDD | 01DC192 | AU1H | 24 |
Lenovo Storage 900GB 10K 2.5″ SAS HDD | 01DC417 | AU1N | 24 |
Lenovo Storage 900GB 15K 2.5″ SAS HDD | 01KP040 | AVP5 | 24 |
Lenovo Storage 1.2TB 10K 2.5″ SAS HDD | 01DC407 | AU1L | 24 |
Lenovo Storage 1.8TB 10K 2.5″ SAS HDD | 01DC402 | AU1K | 24 |
Lenovo Storage 2.4TB 10K 2.5″ SAS HDD | 4XB7A09101 | B103 | 24 |
2.5-inch SAS hot-swap SED HDDs | |||
Lenovo Storage 1.2TB 10K 2.5″ SAS SEDHDD | 01DC412 | AU1M | 24 |
2.5-inch NL SAS hot-swap HDDs | |||
Lenovo Storage 1TB 7.2K 2.5″ NL-SAS HDD | 01DC442 | AU1S | 24 |
Lenovo Storage 2TB 7.2K 2.5″ NL-SAS HDD | 01DC437 | AU1R | 24 |
2.5-inch SAS hot-swap SSDs (1DWD) | |||
Lenovo Storage 1.92TB 1DWD 2.5″ SAS SSD (1200.2) | 4XB7A12067 | B30K | 24 |
Lenovo Storage 3.84TB 1DWD 2.5″ SAS SSD (1200.2) | 01CX632 | AV2F | 24 |
Lenovo Storage 3.84TB 1DWD 2.5″ SAS SSD (PM1633a) | 01KP065 | AVPA | 24 |
Lenovo Storage 7.68TB 1DWD 2.5″ SAS SSD (PM1633a) | 01KP060 | AVP9 | 24 |
Lenovo Storage 15.36TB 1DWD 2.5″ SAS SSD(PM1633a) | 4XB7A08817 | B104 | 24 |
2.5-inch SAS hot-swap SSDs (3DWD) | |||
Lenovo Storage 400GB 3DWD 2.5″ SAS SSD | 01DC482 | AU1V | 24 |
Lenovo Storage 800GB 3DWD 2.5″ SAS SSD | 01DC477 | AU1U | 24 |
Lenovo Storage 1.6TB 3DWD 2.5″ SAS SSD | 01DC472 | AU1T | 24 |
Lenovo Storage 3.84TB 3DWD 2.5″ SAS SSD | 4XB7A12066 | B30J | 24 |
2.5-inch SAS hot-swap SSDs (10DWD) | |||
Lenovo Storage 400GB 10DWD 2.5″ SAS SSD | 01DC462 | AUDK | 24 |
Lenovo Storage 800GB 10DWD 2.5″ SASSSD | 01DC452 | AUDH | 24 |
Lenovo Storage 1.6TB 10DWD 2.5″ SASSSD | 01DC447 | AUDG | 24 |
2.5-inch SAS hot-swap SED SSDs (10DWD) | |||
Lenovo Storage 800GB 10DWD 2.5″ SASSSD (SED) | 01DC457 | AUDJ | 24 |
Power cables
The D1212and D1224 ship standard with two 1.5m, 10A/100-250V, C13 to IEC 320-C14 rack power cables. Other power cable options are also available, and the part numbers and feature codes to order the power cables are listed in the following table (two power cables are required per each D1212and D1224).
Description | Part number | Feature code |
---|---|---|
Rack power cables | ||
1.2m, 10A/100-250V, 2 Short C13s to Short C14 Rack Power Cable | 47C2487 | A3SS |
1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable | 47C2491 | A3SW |
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7937 | 6201 |
2.5m, 10A/100-250V, 2 Long C13s to Short C14 Rack Power Cable | 47C2488 | A3ST |
2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable | 47C2492 | A3SX |
2.8m, 10A/100-250V, 2 Short C13s to Long C14 Rack Power Cable | 47C2489 | A3SU |
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | None* | 6311 |
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable | 39Y7938 | 6204 |
2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable | 47C2493 | A3SY |
4.1m, 10A/100-250V, 2 Long C13s to Long C14 Rack Power Cable | 47C2490 | A3SV |
4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable | 47C2494 | A3SZ |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7932 | 6263 |
Country-specific power cords | ||
10A/125V C13 to NEMA 5-15P 4.3m line cord | 39Y7931 | 6207 |
10A/250V C13 to NEMA 6-15P 2.8m line cord | 46M2592 | A1RF |
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord | 39Y7930 | 6222 |
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord | 39Y7924 | 6211 |
Brazil 10A/250V C13 to NBR 14136 2.8m line cord | 69Y1988 | 6532 |
China 10A/250V C13 to GB 2099.1 2.8m line cord | 39Y7928 | 6210 |
Denmark 10A/250V C13 to DK2-5a 2.8m line cord | 39Y7918 | 6213 |
European 10A/230V C13 to CEE7-VII 2.8m line cord | 39Y7917 | 6212 |
India 10A/250V C13 to IS 6538 2.8m line cord | 39Y7927 | 6269 |
Israel 10A/250V C13 to SI 32 2.8m line cord | 39Y7920 | 6218 |
Italy 10A/250V C13 to CEI 23-16 2.8m line cord | 39Y7921 | 6217 |
Japan 12A/125V C13 to JIS C-8303 2.8m line cord | 46M2593 | A1RE |
Korea 12A/250V C13 to KETI 2.8m line cord | 39Y7925 | 6219 |
South Africa 10A/250V C13 to SABS 164 2.8m line cord | 39Y7922 | 6214 |
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord | 39Y7919 | 6216 |
Taiwan 15A/125V C13/CNS 10917 2.8m line cord | 00CG267 | 6402 |
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord | 39Y7923 | 6215 |
Physical specifications
The D1212and D1224 have the following dimensions and weight (approximate):
- Height: 88 mm (3.5 in.)
- Width: 443 mm (17.4 in.)
- Depth: 630 mm (24.8 in.)
- Maximum weight
- D1212: 26 kg (57.3 lb)
- D1224: 24 kg (52.9 lb)
Operating environment
The D1212and D1224 are supported in the following environment:
- Air temperature:
- Operating: 5 °C to 40 °C (41 °F to 104 °F)
- Storage: -40 °C to +60 °C (-40 °F to 140 °F)
- Maximum altitude: 3,045 m (10,000 ft)
- Humidity:
- Operating: 20% to 80% (non-condensing)
- Storage: 5% to 100% (no precipitation)
- Electrical:
- 100 to 127(nominal) V AC; 50 Hz to 60 Hz; 6.11 A
- 200 to 240 (nominal) V AC; 50 Hz to 60 Hz; 3.05 A
- BTU output: 1979 BTU/hr (580 W)
- Noise level: 6.5 bels
Warranty services and upgrades
The D1212 and D1224 have a three-year customer-replaceable unit (CRU)warranty with standard call center support during normal business hoursand 9×5 Next Business Day Parts Delivered.
Some countries might have different warranty terms and conditions than the standard warranty. This is due to local business practices or laws in the specific country. Local service teams can assist in explaining country-specific terms when needed. Examples of country-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.
If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technicianto the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.
If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spares parts.
Also available are Lenovo Services warrantyupgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For information about Lenovo warranty service upgrade offerings that are available in your country or area, refer tothe following resources:
- Service part numbers in Lenovo Data CenterSolution Configurator(DCSC):
http://dcsc.lenovo.com/#/services - Lenovo Services Availability Locator
http://lenovolocator.com/
In general, the following Lenovo warranty service upgrades are available:
- Warranty and maintenance service upgrades:
- 3, 4, or 5 years of warranty service coverage
- 1-year or 2-year post-warranty extensions
- Foundation Service: 9×5 service coverage with next business day onsite response
- Essential Service: 24×7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select countries)
- Advanced Service: 24×7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select countries)
- Premier Support
Premier Support service offerssingle point of contact for end-to-end problem resolution and collaborative third-party software support with direct access to Lenovo’s most advanced technicians for faster troubleshooting.
- YourDrive YourData
Lenovo’s YourDrive YourData service (where applicable) is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo system. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Foundation, Essential, or Advanced Service upgrades and extensions.
- Basic Hardware Installation Services
Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet,connect to power and network, check and update firmware to the latest levels,verify operation, and dispose of the packaging, allowing your team to focus on other priorities.
For service definitions, country-specific details, and service limitations, please refer to the following documents:
- Lenovo Statement of Limited Warranty for Data Center Group (DCG) Servers and System Storage
http://pcsupport.lenovo.com/us/en/solutions/ht503310 - Lenovo Data Center Services Agreement
http://support.lenovo.com/us/en/solutions/ht116628
Regulatory compliance
The D1212 and D1224drive enclosures conform to the following regulations:
- BSMI CNS 13438, Class A; CNS 14336 (Taiwan)
- CCC GB 4943.1, GB 17625.1,GB 9254 Class A (China)
- CE Mark (European Union)
- CISPR 22, Class A
- EAC (Russia)
- EN55022, Class A
- EN55024
- FCC Part 15, Class A (United States)
- ICES-003/NMB-03, Class A (Canada)
- IEC/EN60950-1
- KC Mark(Korea)
- NOM-019 (Mexico)
- Reduction of Hazardous Substances (ROHS)
- UL/CSA IEC 60950-1
- VCCI, Class A (Japan)
Interoperability
Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The Lenovo Storage D1212 and D1224support attachment to Lenovo ThinkSystem, System x, and ThinkServer hosts.
For end-to-end storage configuration support, refer to the Lenovo Storage D1212 and D1224 Interoperability Matrix that can be found on the following documentation pages:
- Lenovo Storage D1212Documentation
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/d1212/4587/documentation - Lenovo Storage D1224Documentation
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/d1224/4587/documentation
The following sections list adapters, servers, and operating systems supported by Lenovo that can be used with the Lenovo Storage D1212and D1224:
Important:Information that is provided in these sections is for order reference purposes only. Not all possible combinations might be supported. End-to-end storage configuration supportmustbe verified through the Lenovo Storage D1212 and D1224 Interoperability Matrix.
SAS RAID controllers and HBAs
The D1212 and D1224enclosures support the RAID adapters and HBAslisted in the following table.
Description | Part number | Maximumquantityof enclosuresperadapter | |
---|---|---|---|
Single I/Opath |
Dual I/Opath |
||
ThinkSystemadapters | |||
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | 7Y37A01087 | 8 | 8 / 4* |
ThinkSystem 430-8e SAS/SATA 12Gb HBA | 7Y37A01090 | 8 | 8 |
ThinkSystem 430-16e SAS/SATA 12Gb HBA | 7Y37A01091 | 8 | 8 |
System x adapters | |||
ServeRAID M5225-2GB SAS/SATA Controller | 00AE938 | 8 | 8 / 4* |
N2225 SAS/SATA HBA | 00AE912 | 8 | 8 |
N2226 SAS/SATA HBA | 00AE916 | 8 | 8 |
ThinkServeradapters | |||
ThinkServer 9300-8e PCIe 12Gb 8-port External SAS Adapter by LSI | 4XB0F28703 | 8 | 8 |
ThinkServer 8885e PCIe 12Gb 8-port External SAS Adapter by PMC | 4XB0G88727 | 1 | 1 |
* The maximum quantity of D1212 / D1224enclosures.
The following tables summarizefeatures of supported adapters.
Feature | RAID 930-8e | 430-8e HBA | 430-16e HBA |
---|---|---|---|
Formfactor | PCIe LP | PCIe LP | PCIe LP |
SAS controllerchip | SAS3508 | SAS3408 | SAS3416 |
Host interface | PCIe3.0 x8 | PCIe3.0 x8 | PCIe3.0 x8 |
Port interface | 12GbSAS | 12GbSAS | 12GbSAS |
Number of ports | 8 | 8 | 16 |
Connector type | SFF-8644 x4 | SFF-8644 x4 | SFF-8644 x4 |
Number of connectors | 2 | 2 | 4 |
Drive interface | SAS, SATA | SAS, SATA | SAS, SATA |
Drive type | HDD, SSD, SED | HDD, SSD, SED* | HDD, SSD, SED* |
Numberofdevices | 240^ | 1024 | 1024 |
RAID levels | 0/1/10/5/50/6/60 | None | None |
JBOD mode | Yes | Yes | Yes |
Cache | 4 GB (Included) | None | None |
Cacheprotection | Flashbackup(Included) | None | None |
SED key management(SafeStore) | Yes | No | No |
SSD I/O acceleration(FastPath) | Yes | No | No |
SSD Caching(CacheCade Pro 2.0) | No** | No | No |
* HBAs do not support key management for SEDs; third-party host software is responsible for managing the keys.
^ The support for 240 devices requires the firmware version 5.030 or newer and the activation of the profile 12 on the RAID 930-8e controller via UEFI or StorCLI. By default, the profile 10 is activated on the controller, which provides support for up to 64 devices.
** The SSD caching feature has been phased out in the new generation of advanced RAID controllers.
Feature | M5225-2GB | N2225 | N2226 | 9300-8e | 8885e |
---|---|---|---|---|---|
Form factor | Low profile | Low profile | Low profile | Low profile | Low profile |
SAS controller chip | SAS3108 | SAS3008 | SAS3008 | SAS3008 | PM8063 |
Host interface | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 |
Port interface | 12Gbps SAS | 12GbpsSAS | 12GbpsSAS | 12GbpsSAS | 12GbpsSAS |
Numberof ports | 8 | 8 | 16 | 8 | 8 |
Connector type | SFF-8644 x4 | SFF-8644 x4 | SFF-8644 x4 | SFF-8644 x4 | SFF-8644 x4 |
Number ofconnectors | 2 | 2 | 4 | 2 | 2 |
Drive interface | SAS | SAS | SAS | SAS | SAS |
Drive type | HDD,SSD,SED | HDD,SSD,SED* | HDD,SSD,SED* | HDD,SSD,SED* | HDD,SSD,SED* |
Numberofdevices | 240 | 1024 | 1024 | 1024 | 256 |
RAID levels | 0/1/10/5/50; Optional 6/60 (47C8706) |
None | None | None | None |
JBOD mode | No | Yes | Yes | Yes | Yes |
Cache | 2 GB (Included) | None | None | None | 1 GB |
Cache protection | Flash backup (Included) |
None | None | None | None |
SEDkeymanagement (SafeStore) |
Yes | No | No | No | No |
SSD I/O acceleration (FastPath) |
Optional (47C8710) |
No | No | No | No |
SSD Caching (CacheCade Pro 2.0) |
Optional (47C8712) |
No | No | No | No |
* HBAs do not support key management for SEDs; third-party host software is responsible for managing the keys.
Servers
The D1212 and D1224 expansion enclosures are supported with Lenovo servers that support the RAID controllersand HBAslisted in the SAS RAID controllers and HBAs section, including the following Lenovo rack-mount servers:
- ThinkSystem
- ThinkSystem SR530 Types 7X07 and 7X08
- ThinkSystem SR550 Types 7X03 and 7X04
- ThinkSystem SR570 Types 7Y02 and 7Y03
- ThinkSystem SR590 Types 7X98 and 7X99
- ThinkSystem SR630 Types 7X01 and 7X02
- ThinkSystem SR650 Types 7X05 and 7X06
- ThinkSystem SR850 Types 7X18 and 7X19
- ThinkSystem SR950 Types 7X11,7X12, and 7X13
- System x
- System x3250 M5 Type 5458
- System x3550 M5 Type 5463
- System x3550 M5 Type 8869
- System x3650 M5 Type 5462
- System x3650 M5 Type 8871
- System x3750 M4 Type 8753
- System x3850X6 Type 6241 (E7 v2, E7 v3, andE7 v4)
- System x3950 X6 Type 6241 (E7 v2, E7 v3, and E7 v4)
- ThinkServer
- ThinkServerRS160(E3-1200 v5,E3-1200 v6, Core i3, Pentium G,and Celeron G Series)
- ThinkServerRD350 (E5-2600 v3 and E5-2600 v4)
- ThinkServerRD450 (E5-2600 v3 and E5-2600 v4)
- ThinkServerRD550 (E5-2600 v3 and E5-2600 v4)
- ThinkServerRD650 (E5-2600 v3 and E5-2600 v4)
For RAID adapters and HBAssupport details for a particular server, refer to aLenovoPressproduct guide for theserver, foundat: http://lenovopress.com
Operating systems
The D1212 and D1224 expansion enclosures support the following operating systems:
- Microsoft:
- Microsoft Windows Server 2016
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2008 R2
- Red Hat:
- Red Hat Enterprise Linux 7.3
- Red Hat Enterprise Linux 7.2
- Red Hat Enterprise Linux 6.8 Server x64 Edition
- Red Hat Enterprise Linux 6.7 Server x64 Edition
- SUSE:
- SUSE Linux Enterprise Server 12 SP2
- SUSE Linux Enterprise Server 12 SP1
- SUSE Linux Enterprise Server 12
- SUSE Linux Enterprise Server 11 SP4 for AMD64/EM64T
- VMware:
- VMware vSphere 6.5 (ESXi)
- VMware vSphere 6.0 (ESXi)Update 3
- VMware vSphere 6.0 (ESXi)Update 2
- VMware vSphere 6.0 (ESXi)Update 1
- VMware vSphere 6.0 (ESXi)
- VMware vSphere 5.5 (ESXi) Update 3
For information about operating systemcompatibility with Lenovo servers, refer to the Operating System Interoperability Guide:http://lenovopress.com/osig
Rack cabinets
The following table lists the rack cabinets that are offered by Lenovo that can be used in D1212 and D1224storageexpansion solutions.
Description | Part number |
---|---|
25U S2 Standard Rack(1000 mm deep; 2 sidewall compartments) | 93072RX |
25U Static S2 Standard Rack(1000 mm deep; 2 sidewall compartments) | 93072PX |
42U S2 Standard Rack(1000 mm deep; 6 sidewall compartments) | 93074RX |
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) | 93634PX |
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) | 93634EX |
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) | 93604PX |
42U 1200mm Deep Static Rack (6 sidewall compartments) | 93614PX |
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) | 93084PX |
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) | 93084EX |
For more information, see the list of Product Guides in the Rack Cabinets category:
http://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in D1212 and D1224 storage expansion solutions.
Description | Part number |
---|---|
0U Basic PDUs | |
0U 36 C13/6 C19 24A/200-240V 1 Phase PDUwith NEMA L6-30P line cord | 00YJ776 |
0U 36 C13/6 C19 32A/200-240V 1 Phase PDUwith IEC60309 332P6 line cord | 00YJ777 |
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDUwith IEC60309 532P6linecord | 00YJ778 |
0U 21 C13/12 C19 48A/200-240V 3 Phase PDUwith IEC60309 460P9 line cord | 00YJ779 |
Switched and Monitored PDUs | |
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1PhPDUw/NEMA L6-30Plinecord | 00YJ781 |
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1PhPDU w/IEC60309 332P6linecord | 00YJ780 |
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3PhPDU w/ IEC60309 532P6 cord | 00YJ782 |
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3PhPDU w/ IEC60309 460P9linecord | 00YJ783 |
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) | 46M4002 |
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord | 46M4003 |
1U 12 C13 Switched and Monitored DPI PDU (without line cord) | 46M4004 |
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord | 46M4005 |
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |
Ultra Density Enterprise C19/C13 PDU Module (without line cord) | 71762NX |
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord | 71763NU |
C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |
DPI C13 Enterprise PDU+ (without line cord) | 39M2816 |
DPI Single Phase C13 Enterprise PDU (without line cord) | 39Y8941 |
C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |
DPI Single Phase C19 Enterprise PDU (without line cord) | 39Y8948 |
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord | 39Y8923 |
Front-end PDUs (3x IEC 320 C19 outlets) | |
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord | 39Y8938 |
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord | 39Y8939 |
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8934 |
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8940 |
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8935 |
Universal PDUs (7x IEC 320 C13 outlets) | |
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) | 00YE443 |
NEMA PDUs (6x NEMA 5-15R outlets) | |
DPI 100-127V PDU with fixed NEMA L5-15P line cord | 39Y8905 |
Line cords for PDUs that ship without a line cord | |
DPI 30a Line Cord (NEMA L6-30P) | 40K9614 |
DPI 32a Line Cord (IEC 309 P+N+G) | 40K9612 |
DPI 32a Line Cord (IEC 309 3P+N+G) | 40K9611 |
DPI 60a Cord (IEC 309 2P+G) | 40K9615 |
DPI 63a Cord (IEC 309 P+N+G) | 40K9613 |
DPI Australian/NZ 3112 Line Cord (32A) | 40K9617 |
DPI Korean 8305 Line Cord (30A) | 40K9618 |
For more information, see the list of Product Guides in the PDU category:
http://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in D1212 and D1224 storage expansion solutions.
Description | Part number |
---|---|
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12Aoutlets) | 55941AX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8xIEC 320 C13 10A outlets) | 55941KX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets) | 55942AX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8xIEC 320 C13 10A, 1x IEC 320 C19 16A outlets) | 55942KX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA 5-20R 16A, 1x NEMA L5-30R 24A outlets) | 55943AX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8xIEC 320 C13 10A, 1x IEC 320 C19 16A outlets) | 55943KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC)(8xIEC 320 C13 10A, 2x IEC 320 C19 16A outlets) | 55945KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8xIEC 320 C13 10A, 2x IEC 320 C19 16A outlets) | 55946KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) | 55948KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) | 55949KX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) | 55948PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) | 55949PX |
For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.
For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovofs.com
Related product families
Product families related to this document are the following: